Digital Motor Protection Relay

The MPR 2000 monitors three phase & ground currents, voltages, and temperature inputs to provide one of the most comprehensive motor protectionpackages available. Wth up to 10 temperature sensors, the MPR 2000 monitors as many as 39 programmable protective functions. It is ideal for high voltage motors, large low voltage motors, and applications where full protection and advanced warning is crucial, such as in the process and chemical industries.

MPC 2000 Digital Motor Protection and Control Relay

Similar to the MPR 2000 except that it also incorporates advancedcontrol capabilities for all types of starting methods, including softstarters and variable frequency drives.
The MPC 2000 has been specifically designed for integration into motor management systems in chemical, petrochemical and other process systems.

Motor Protection And Control

   1. Max start time
   2. Too many starts
   3. Undercurrent pre-alarm
   4. Undercurrent trip
   5. Load increase
   6. Stall protection
   7. Short circuit
   8. Overload
   9. Earth Fault pre-alarm
10. Earth Fault trip
11. Unbalance current alarm
12. Unbalance current trip
13. Thermal pre-alarm
14. Thermal trip
15. Under-voltage
16. Over-voltage pre-alarm
17. Over-voltage trip
18. Phase loss
19. Phase sequence
20. Temp. 1 Pre-alarm and trip (separate setting is available for temp sensor trip)
21. Temp. 2 Pre-alarm and trip
22. Temp. 3 Pre-alarm and trip
23. Temp. 4 Pre-alarm and trip
24. Temp. 5 Pre-alarm and trip
25. Temp. 6 Pre-alarm and trip
26. Temp. 7 Pre-alarm and trip
27. Temp. 8 Pre-alarm and trip
28. Temp. 9 Pre-alarm and trip
29. Temp. 10 Pre-alarm and trip

Each protection can be designated as:
     * Trip (or Trip Fail-safe)
     * Alarm Fail-safe
     * Auto Reset
     * Panel Reset
     * Comm. Reset

Discrete Logic Inputs (MPC 2000 Only):
* Local Start A/B
* Local/Remote
* PLC Reset
* Speed Switch
* Isolator
* External Faults 1,2,3
* Contactor A/B Aux Relay
* Local Stop
* PLC/Serial Port
* PLC Control
* Plant Interlock
* Contactor A/B Status

Communications

Full access through : RS485 with Modbus protocol

True R.M.S. Measurements

* Voltage, Current, and Resistance at sampling rate of 0.5msec
* Available with 10 RTDs or 3 Thermistors and 2 RTD's

Outputs - 4 Relays

* Programmable for Overload, KWHR (energy) Pulse Initiator, or Slave for Alarm
* Earth Fault
* Alarm (Fail Safe)
* Trip (Fail Safe)

Displays - LCD

Measured data :
    Voltage - phase to phase
    Voltage - phase to neutral
    Current each phase
    Earth fault current
    Resistance each RTD/Thermistor
    Power
    Power Factor

Calculated data :
    Motor current in % of FLC
    Thermal capacity
    Time to trip
    Time to start (after fault)
    Unbalanced current

Statistical data :
    Total run time
    Total number of starts
    Total number of trips
    Last start time period
    Last start current peak
    Energy

Fault data :
    Last trip
    Last alarm
    Trip current each phase
    Trip earth fault current
    Trip voltage (each phase)
Displays - LED's (MPR)

* On
* Stopped
* Starting


* Running
* O/L Trip
* E/F Trip


* Alarm
* Trip
* Internal Failure


Displays - LED's (MPC)

* On
* Stopped
* Starting
* Running
* Contactor A
* Contactor B
* Alarm
* Trip
* Internal Failure
Typical Applications

* High voltage and large low voltage motors
* Motors in the Process Industry
* Critical motors requiring special protection and/or supervision
 
 
 